Re: Retirement Plans for R44/46?

Posted by Jeff H. on Tue Feb 15 03:54:58 2005, in response to Re: Retirement Plans for R44/46?, posted by Bill from Maspeth on Sun Feb 13 23:22:38 2005.

edf40wrjww2msgDetail:detailStr
The R-44 WESTCODE brake package does not use a feed valve and
therefore the brake pipe will charge up to the compressor
governor cut-out pressure. If there are no significant leaks
in the brake pipe, that pressure will remain sealed in, but if
there is a leak, there is no "excess pressure" in the main
reservoirs above brake pipe pressure, so it will fall.

This isn't really a problem since it is the rate of brake pipe fall
which causes a BIE, not the absolute pressure. As long as the BP
stays above about 70#, the emergency contactors will stay in.